Lamp change - Fig 13
Take the new lamp out of its package and insert in the fitting.
WARNING: do not touch the lamps envelope with bare hands.
Should this happen, clean the bulb with a cloth soaked in alcohol
and dry it with a clean, dry cloth.
IMPORTANT: Make sure the lamp is inserted with the external
contact (A) facing the elliptical reflector’s slot.
Lamp regulation - Fig. 14
To centre the lamp, turn the three adjusting screws as shown in the figure.